Difference between revisions of "SIMarchitect Library Overview/Component library/Powertrain/Rechargeable Energy Storage System/Battery"
From OpenMBD
< SIMarchitect Library Overview | Component library | Powertrain | Rechargeable Energy Storage System
(→Module Parameter) |
(→Module Parameter) |
||
Line 75: | Line 75: | ||
| % | | % | ||
|- | |- | ||
− | | rowspan="2" style="text-align: | + | | rowspan="2" style="text-align: left;" | e |
| dat.ocv.soc.vec | | dat.ocv.soc.vec | ||
| rowspan="2" style="text-align: left;" | Open circuit voltage = f(state of charge) | | rowspan="2" style="text-align: left;" | Open circuit voltage = f(state of charge) | ||
Line 83: | Line 83: | ||
| V | | V | ||
|- | |- | ||
− | | rowspan="4" style="text-align: | + | | rowspan="4" style="text-align: left;" | Discharge R<sub>0 </sub>, R and C |
| dat.resi.discharge.soc.vec | | dat.resi.discharge.soc.vec | ||
| rowspan="4" style="text-align: left;" | Discharge R<sub>0 </sub> = f(state of charge) <br/> Discharge R = f(state of charge) <br/> Discharge C = f(state of charge) | | rowspan="4" style="text-align: left;" | Discharge R<sub>0 </sub> = f(state of charge) <br/> Discharge R = f(state of charge) <br/> Discharge C = f(state of charge) | ||
Line 97: | Line 97: | ||
| F | | F | ||
|- | |- | ||
− | | rowspan="4" style="text-align: | + | | rowspan="4" style="text-align: left;" | Charge R<sub>0 </sub>, R and C |
| dat.resi.discharge.soc.vec | | dat.resi.discharge.soc.vec | ||
| rowspan="4" style="text-align: left;" | Charge R<sub>0 </sub> = f(state of charge) <br/> Charge R = f(state of charge) <br/> Charge C = f(state of charge) | | rowspan="4" style="text-align: left;" | Charge R<sub>0 </sub> = f(state of charge) <br/> Charge R = f(state of charge) <br/> Charge C = f(state of charge) |
Revision as of 09:29, 9 April 2018
Contents
General information about Battery
test
Module
Bus Selector for module input
Module output
Output | ||||
---|---|---|---|---|
Node | Variable | Label | Description | Unit |
Sensor | i | Batt_iAct_A | Battery current output | A |
u | Batt_uAct_V | Battery output voltage | V | |
SOC | Batt_soc_Act_Rt | State of Charge | ratio (0-1) | |
ϑbatt | Batt_tAct_K | Battery temperature | K | |
elec out [V] | u | phys_voltage_V | voltage | V |
Module Parameter
Variable | Parameter | Description | Unit |
---|---|---|---|
ns | dat.ns.value | Number of cells connected in series | - |
np | dat.np.value | Number of cells connected in parallel | - |
C | dat.capacity.value | Cell capacity | Ah |
SOC(0) | dat.initialSOC.value | Initial state of charge (as % of cell capacity) | % |
e | dat.ocv.soc.vec | Open circuit voltage = f(state of charge) | % |
dat.ocv.ocv.vec | V | ||
Discharge R0 , R and C | dat.resi.discharge.soc.vec | Discharge R0 = f(state of charge) Discharge R = f(state of charge) Discharge C = f(state of charge) |
% |
dat.resi.discharge.R0.vec | Ω | ||
dat.resi.discharge.R.vec | Ω | ||
dat.resi.discharge.C.vec | F | ||
Charge R0 , R and C | dat.resi.discharge.soc.vec | Charge R0 = f(state of charge) Charge R = f(state of charge) Charge C = f(state of charge) |
% |
dat.resi.charge.R0.vec | Ω | ||
dat.resi.charge.R.vec | Ω | ||
dat.resi.charge.C.vec | F |